{"id":3871,"date":"2026-06-23T11:17:51","date_gmt":"2026-06-23T09:17:51","guid":{"rendered":"https:\/\/fixsus.be\/the-weather-remains-unchanged-and-your-building-is-sweating-along-with-it\/"},"modified":"2026-10-20T12:56:43","modified_gmt":"2026-10-20T10:56:43","slug":"the-weather-remains-unchanged-and-your-building-is-sweating-along-with-it","status":"publish","type":"post","link":"https:\/\/fixsus.be\/en\/the-weather-remains-unchanged-and-your-building-is-sweating-along-with-it\/","title":{"rendered":"The weather remains unchanged. And your building is sweating along with it."},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\" style=\"margin-top:0;margin-bottom:var(--wp--preset--spacing--48-32)\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"745\" src=\"https:\/\/fixsus.be\/wp-content\/uploads\/2026\/07\/armand-pien-1024x745.jpg\" alt=\"\" class=\"wp-image-1880\" srcset=\"https:\/\/fixsus.be\/wp-content\/uploads\/2026\/07\/armand-pien-1024x745.jpg 1024w, https:\/\/fixsus.be\/wp-content\/uploads\/2026\/07\/armand-pien-300x218.jpg 300w, https:\/\/fixsus.be\/wp-content\/uploads\/2026\/07\/armand-pien-768x559.jpg 768w, https:\/\/fixsus.be\/wp-content\/uploads\/2026\/07\/armand-pien-1536x1117.jpg 1536w, https:\/\/fixsus.be\/wp-content\/uploads\/2026\/07\/armand-pien-2048x1490.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p class=\"wp-block-paragraph\"><em>&#8220;Good evening, dear viewers.&#8221;<\/em> During the legendary heatwave of 1976, now fifty years ago, our most famous weatherman eventually reached a point where he no longer knew what to write. For seventeen consecutive days, temperatures rose above thirty degrees, and in his weather report for the newspaper, he finally settled on four words: <em>&#8220;The weather remains unchanged.&#8221;<\/em> With that same sobriety, he observed the jet stream, which he believed determined the entire Western European weather, and explained the most complex phenomena as if they were logic itself. <\/p>\n\n<p class=\"wp-block-paragraph\">This week, the mercury is pushing those limits again, and the daily records from 1976 are on the verge of being broken. In many care centers, government buildings, and offices, the same scenario is unfolding: the chillers are running at full capacity, people on the south side complain that it is impossible to keep cool, and consumption peaks at the most expensive time of day. The first thought is often that there is insufficient cooling capacity. Understandable, but rarely the correct explanation. Usually, the capacity is not too small. The control system is.     <\/p>\n\n<h2 class=\"wp-block-heading\">Cool or comfortable?<\/h2>\n\n<p class=\"wp-block-paragraph\">Comfort is more than just a number on the thermostat. At high temperatures, humidity also plays a major role. A room at 24 degrees feels stifling if the humidity is too high, and people then demand even more cooling while the real problem lies elsewhere. Those who only control based on temperature are missing half the story.   <\/p>\n\n<h2 class=\"wp-block-heading\">Every system for itself<\/h2>\n\n<p class=\"wp-block-paragraph\">In large buildings, the technology is usually already installed: external sun protection, ventilation with heat recovery, cooling, and sometimes windows that can open automatically. However, each system operates independently. The sun protection is linked to a fixed clock and closes too late, so the heat is already inside before anything moves. The ventilation brings in warm air during the day, while the cool night air remains unused. And the cooling has to compensate for a load that should never have been there. Three systems working against each other, and you pay twice: in comfort and on the bill.     <\/p>\n\n<h2 class=\"wp-block-heading\">First repel, then cool<\/h2>\n\n<p class=\"wp-block-paragraph\" id=\"ember1085\">The logic is simple, however. First, keep the heat out. Then, exhaust what is already inside. And only after that, cool mechanically. Most buildings skip the first two steps and start immediately with the most expensive one.    <\/p>\n\n<p class=\"wp-block-paragraph\" id=\"ember1086\">That is where the profit lies. Fixsus has been building open building management systems for these types of buildings for years. With TIBA3, you bring your existing installations under a single control system without replacing anything. You retain what is there and link it together. The sun protection closes per facade before the heat enters. Night cooling cools the thermal mass with outside air as soon as it drops below the indoor temperature at night, so you start the day with a cool building. And on a tropical night like the upcoming Thursday, when it remains 25 degrees outside and no weatherman can promise you relief, the system simply does not engage that night cooling, as you would be bringing in warm air instead of cool. The system weighs this itself based on measured temperatures. The cooling regulates per zone based on actual temperature, humidity, and occupancy, so an empty wing requires no cooling. And the chiller only kicks in when the rest is insufficient.         <\/p>\n\n<h2 class=\"wp-block-heading\">First measure, then control<\/h2>\n\n<p class=\"wp-block-paragraph\" id=\"ember1088\">The regulation is only as good as what you measure. That is why you place sensors in the rooms themselves, not just in the technical room or the hallway. A sensor per zone measures temperature, humidity, and presence, and adjusts accordingly where it actually matters: in the resident&#8217;s room, in the office, in the meeting room. This way, you regulate based on what people feel, not on an average that is never accurate.   <\/p>\n\n<p class=\"wp-block-paragraph\" id=\"ember1089\">Because everything converges into one system, you can also see what is happening. Which zones remain warm or humid, where the cooling starts too early, or whether an intervention is effective. No guesswork, but an installation that you can adjust purposefully. In a care center with vulnerable residents or in a busy office, that makes the difference.   <\/p>\n\n<p class=\"wp-block-paragraph\" id=\"ember1090\">The result: a better indoor climate, fewer complaints, and a lower peak on the toughest days. All on an installation that was already largely in place. <\/p>\n\n<h2 class=\"wp-block-heading\">The heatwave as an honest test<\/h2>\n\n<p class=\"wp-block-paragraph\" id=\"ember1092\">A heatwave is an honest test. It is not the technology that makes the difference, but the control. We do not speak of smart buildings, but of technologies that work together smartly. That is what Fixsus stands for.   <\/p>\n\n<p class=\"wp-block-paragraph\" id=\"ember1093\">We cannot stop the weather. But as the weatherman already knew back then: there is still much to be said about a dry subject like the weather. Fortunately, there is even more to say about a well-managed building. \u201c<em>Good evening, dear viewers, and keep it cool.<\/em>&#8220;<\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<div class=\"wp-block-columns download-item has-white-50-background-color has-background is-layout-flex wp-container-core-columns-is-layout-68dda7a4 wp-block-columns-is-layout-flex\" style=\"border-radius:999px;padding-top:var(--wp--preset--spacing--12-8);padding-right:var(--wp--preset--spacing--24-16);padding-bottom:var(--wp--preset--spacing--12-8);padding-left:var(--wp--preset--spacing--24-16)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30px\">\n<div class=\"wp-block-outermost-icon-block\"><div class=\"icon-container\" style=\"width:28px;transform:rotate(0deg) scaleX(1) scaleY(1)\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"28\" height=\"26\" viewbox=\"0 0 28 26\" fill=\"none\"><g clip-path=\"url(#clip0_43464_6889)\"><path d=\"M26.6201 23.2617H1.38071C1.00882 23.2617 0.65217 23.406 0.389208 23.6628C0.126246 23.9197 -0.0214844 24.268 -0.0214844 24.6313C-0.0214844 24.9945 0.126246 25.3428 0.389208 25.5997C0.65217 25.8565 1.00882 26.0008 1.38071 26.0008H26.6201C26.992 26.0008 27.3487 25.8565 27.6116 25.5997C27.8746 25.3428 28.0223 24.9945 28.0223 24.6313C28.0223 24.268 27.8746 23.9197 27.6116 23.6628C27.3487 23.406 26.992 23.2617 26.6201 23.2617Z\" fill=\"#EE8B66\"><\/path><path d=\"M14.0009 -0.0195312C13.629 -0.0195312 13.2724 0.12476 13.0094 0.3816C12.7465 0.63844 12.5987 0.98679 12.5987 1.35002V15.8535L7.98551 11.334C7.72148 11.0761 7.36337 10.9312 6.98996 10.9312C6.61655 10.9312 6.25844 11.0761 5.9944 11.334C5.73037 11.5919 5.58203 11.9417 5.58203 12.3064C5.58203 12.6711 5.73037 13.0209 5.9944 13.2788L13.0054 20.1265C13.1357 20.2549 13.2908 20.3568 13.4617 20.4263C13.6325 20.4958 13.8158 20.5316 14.0009 20.5316C14.186 20.5316 14.3693 20.4958 14.5402 20.4263C14.711 20.3568 14.8661 20.2549 14.9965 20.1265L22.0074 13.2788C22.1382 13.1511 22.2419 12.9995 22.3126 12.8326C22.3834 12.6658 22.4198 12.487 22.4198 12.3064C22.4198 12.1258 22.3834 11.947 22.3126 11.7801C22.2419 11.6133 22.1382 11.4617 22.0074 11.334C21.8767 11.2063 21.7215 11.105 21.5507 11.0359C21.3798 10.9668 21.1968 10.9312 21.0119 10.9312C20.827 10.9312 20.6439 10.9668 20.4731 11.0359C20.3023 11.105 20.1471 11.2063 20.0163 11.334L15.4031 15.8535V1.35002C15.4031 0.98679 15.2554 0.63844 14.9924 0.3816C14.7295 0.12476 14.3728 -0.0195312 14.0009 -0.0195312Z\" fill=\"#EE8B66\"><\/path><\/g><defs><clippath id=\"clip0_43464_6889\"><rect width=\"28\" height=\"26\" fill=\"white\"><\/rect><\/clippath><\/defs><\/svg><\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-container-core-column-is-layout-55eeb52e wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-bottom:0\"><h3 style=\"margin-top:0;margin-bottom:0\" class=\"link-wrapper wp-block-post-title has-hero-body-text-font-size\"><a href=\"https:\/\/fixsus.be\/en\/the-weather-remains-unchanged-and-your-building-is-sweating-along-with-it\/\" target=\"_self\" >The weather remains unchanged. And your building is sweating along with it.<\/a><\/h3>\n\n<div style=\"padding-top:0;padding-bottom:0;margin-top:0;margin-bottom:0\" class=\"wp-block-post-excerpt\"><p class=\"wp-block-post-excerpt__excerpt\">On repelling heat, cooling, measuring, and controlling. <\/p><\/div><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>On repelling heat, cooling, measuring, and controlling.<\/p>\n","protected":false},"author":3,"featured_media":4945,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[151,145],"class_list":["post-3871","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energy-and-climate","category-vision-and-background"],"acf":[],"_links":{"self":[{"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/posts\/3871","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/comments?post=3871"}],"version-history":[{"count":1,"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/posts\/3871\/revisions"}],"predecessor-version":[{"id":3872,"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/posts\/3871\/revisions\/3872"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/media\/4945"}],"wp:attachment":[{"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/media?parent=3871"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fixsus.be\/en\/wp-json\/wp\/v2\/categories?post=3871"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}