Care
over onze systemen en diensten.
Are there additional monitoring systems for critical rooms?
Are there additional monitoring systems for critical rooms?
Yes. Critical rooms can be equipped with their own monitoring and alarm systems.
Standard integrable monitoring systems
Server room climate control, cold storage, and -80 °C monitoring are standard integrable technologies, featuring dedicated alarms and, if desired, redundant measurement.
Reported before damage occurs
The goal is always the same: a problem is reported before any damage occurs — to servers, samples, or stock.
Can nurse call and building management be integrated into a single system?
Can nurse call and building management be integrated into a single system?
Yes. Fixsus Cura combines nurse call, room control, presence registration, and climate information into a single room solution, managed within the open building management platform.
A single room solution
The Cura Base Station integrates nurse call, badge sign-in, and climate measurement into a single wall-mounted unit. The Cura Pager provides residents with peace of mind through illuminated buttons and a short vibration confirming the call has been sent. With the Cura Pager Domo, they can also control lighting and sun blinds from their bed. Where only a wall-mounted call button is required, the Cura Base Badge is sufficient.
No parallel systems
Nurse call no longer runs alongside building technology, but within it. No duplicate infrastructure, no separate supplier, and no second system to maintain.
For new construction and renovation
The solution is maintenance-friendly and suitable for both new construction and renovation projects. In this way, the care room becomes the starting point of a building architecture that functions today and expands tomorrow.
How is the installation protected against power failure?
How is the installation protected against power failure?
The central control system can be connected to a UPS.
Bridging and clean restarting
The UPS allows the PLC and communication to bridge a power interruption, after which everything restarts cleanly.
Monitoring of critical processes
Critical processes such as server rooms and cold storage facilities receive monitoring that also reports power incidents. This ensures that an interruption does not go unnoticed.
Is the hardware suitable for demanding or critical environments?
Is the hardware suitable for demanding or critical environments?
Yes — these are industrial automation components that also operate in production environments.
Industrial as a starting point
The components are built for continuous operation in industrial conditions — a more demanding regime than what a building typically requires.
Options for critical applications
For critical applications such as server rooms, cold storage, -80 °C monitoring, or healthcare environments, monitoring and redundancy options are available, ensuring that issues are reported before damage occurs.
What if our nurse call system is no longer supported?
What if our nurse call system is no longer supported?
Various manufacturers are phasing out their support for nurse call systems. As long as everything is working, there seems to be no problem. However, without support, every defect becomes a risk.
Why waiting is risky
Spare parts become scarce, knowledge disappears, and in the event of a malfunction, your organization is on its own. Especially with nurse calls, this is unacceptable: a call that does not arrive is not a technical detail.
Switching without interruption
With Fixsus Cura, you switch to a call system that is part of the building management system. The transition takes place room by room, existing cabling is reused where possible, and residents do not need to move. The wall components fit into a standard flush-mounting box with BTicino finishing, so that existing rooms can also be included.
25 years of guaranteed support
You are not choosing a standalone care solution, but a structural integration on an open platform, with 25 years of guaranteed support. This way, you choose when to renew.
Which building technologies can be integrated with TIBA3?
Which building technologies can be integrated with TIBA3?
TIBA3 can bring a wide range of building technologies together into one central management system.
Climate and comfort
This includes heating, cooling, ventilation, air handling, sun protection, screens, climate ceilings, and server room climate control.
Lighting and room functions
Lighting, occupancy detection, lux measurement, room controls, assistance calls, and other local functions can also be integrated.
Energy and infrastructure
TIBA3 can incorporate energy and water metering, geothermal energy, heating networks, charging station control, load balancing, leak detection, and cold storage monitoring into the central control system.
Access and building usage
Access control, badge readers, parking detection, people counting, and other systems that provide information on building usage can also be linked.
Integrated operation
Because these technologies exchange information with each other, they can not only be monitored centrally but also controlled as a single cohesive unit.
Which specific technologies are integrated depends on the building, the existing installations, and the objectives of the project.
Which field devices does Fixsus manufacture in-house?
Which field devices does Fixsus manufacture in-house?
Fixsus develops and builds its own range of field devices, designed to integrate seamlessly into the TIBA3 architecture.
The proprietary range
The range includes, among others:
- the TP10 control panel;
- the Fixsus room controller (terminal unit controller);
- PIR motion detectors with lux measurement;
- room sensors;
- fire damper controllers;
- Fixsus Cura for nurse calls and room control;
- badge readers, remote and wall controls;
- DIN-rail I/O boards.
No closed logic
The devices do not contain project-specific logic and communicate via open standards. As a result, they are easy to replace and can also be used outside of TIBA3.
Which types of buildings is TIBA3 suitable for?
Which types of buildings is TIBA3 suitable for?
TIBA3 has been developed for professional buildings where multiple technical installations must be centrally controlled and monitored.
Broadly applicable
Fixsus works for cities and municipalities, government buildings, service companies, financial institutions, healthcare facilities, hotels, schools, industrial buildings, and real estate projects, among others.
From a single building to multiple sites
TIBA3 can be applied in a single building, but also across an entire building portfolio. Multiple sites can be monitored centrally, while each building retains its own techniques, settings, and visualization.
Scalable according to needs
The solution is always tailored to the scale of the project, the existing installations, the use of the building, and the needs of the manager and users.
Let's get introduced